18,000 – 129,600 GPD

18,000 – 129,600 GPD 2017-08-09T17:08:27-07:00

INDUSTRIAL REVERSE OSMOSIS

WATER FILTRATION SYSTEMS

Electricity is the most expensive cost of any reverse osmosis system. The pumps utilized on the AmeriWater HRO series of industrial reverse osmosis systems use the highest efficiency Class I (EFFI) motors, resulting in reduced energy consumption and consequently reduced operating costs. In addition, the FILMTECTM high productivity, low energy membranes utilized require less pressure to function. Large 34-mil spacer Industrial Reverse Osmosis System – HRO Seriesoptimized for pressure drop minimization reduces the impact of fouling and enhances the cleaning efficiency. The iLECTM technology (interlocking connectors) enables sustained higher quality permeate throughout the life of the element by dramatically reducing the potential for seal leakage and reduces energy consuming flow resistance, resulting in lower operating costs

  • Pump with high efficiency Class I (EFFI) motor
  • High productivity, low energy membranes

  • Horizontal or vertical configuration

  • Interlocking connectors (iLECTM) technology

  • One micron stainless steel cartridge prefilter

  • Powder coated aluminum frame

  • Product flow meter

  • Concentrate reject flow meter with valve

  • Stainless liquid filled pressure gauges for prefilter, post filter, pump, and reject

  • Sample ports on each vessel

  • Digital microprocessor with current hours, conductivity, % rejection, temperature, tank high and low contacts, pretreat lockout, alarm contacts, low feed PSI alarm, and high conductivity alarm

  • Automatic inlet shut off valve

GALLONS PER DAY* 18,000 27,000 28,800 43,200 57,600
Product Flow GPM* 12.5 18.75 20 30 40
Number of Membranes 2 3 4 6 8
Array 1-1 1-1-1 1-1 2-1 2-2
Membrane Model No. R22-8042
Configuration Vertical Horizontal
Pump HP, 3 Ph 5 15
FLA 230V 15.2 42
FLA 460V 7.6 21
FLA 575V 6.1 17
Shipping Weight 915 1,050 1,200 2,000 2,800
Dimensions In. (W x D x H) 55 X 28 X 75 108 X 32 X 72
* Permeate flow based on the following standard test conditions: 2000 ppm NaCl, 150 psi, 77F, pH 8 and 15% recovery. A complete water analysis and computer modeling is necessary for an accurate permeate flow.
Model numbers begin with 00HRO then the gallons. Examples: 00HRO18000 or 00HRO576000
GALLONS PER DAY* 64,800 86,400 108,000 129,600
Product Flow GPM* 45 60 75 90
Number of Membranes 9 12 15 18
Array 2-1 2-2 2-2-1 3-2-1
Membrane Model No. R22-8042
Configuration Horizontal
Pump HP, 3 Ph 15 20
FLA 230V 42 54
FLA 460V 21 27
FLA 575V 17 22
Shipping Weight 2,950 3,300 4,120 4,935
Dimensions In. (W x D x H) 148 X 32 X 72
* Permeate flow based on the following standard test conditions: 2000 ppm NaCl, 150 psi, 77F, pH 8 and 15% recovery. A complete water analysis and computer modeling is necessary for an accurate permeate flow.
Model numbers begin with 00HRO then the gallons. Examples: 00HRO18000 or 00HRO576000

SPECIFICATIONS

  • Design Temperature: 77°F
  • Operation Temperature: 50 – 90°F

  • Minimum Inlet Pressure: 20 PSI

  • Nominal Rejection: 95 – 98%

  • Recovery: 50 – 75% (adjustable)

  • Pump Operation PSI: 180 – 225